Skip to content

smart IoT project using C# for Modbus hybrid inverter, connect with AWS cloud via MQTT, control Builing by BMS

Notifications You must be signed in to change notification settings

topone-engineer/SolarEnergyManagement

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

5 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

SolarEnergyManagement

This document outlines the technical specifications for the design and implementation of a Smart PV/Generator Energy Management System. The system integrates multiple energy sources, including a PV system, Diesel Generator, Hybrid Inverter, and Battery, with an IoT Building Management System (BMS) and a central Smart Energy Management System.

Tables

CREATE TABLE Strategy ( ID INTEGER PRIMARY KEY, Descrition TEXT (100) NOT NULL );

CREATE TABLE Register ( ID INTEGER PRIMARY KEY AUTOINCREMENT, Name TEXT (30) NOT NULL, Type TEXT (20) NOT NULL, Address INTEGER (5) NOT NULL, VarType TEXT (20) NOT NULL, Unit TEXT (10) );

CREATE TABLE StrategyDetail ( ID INTEGER PRIMARY KEY, StrategyID INTEGER (5) REFERENCES Strategy (ID) ON DELETE CASCADE ON UPDATE CASCADE, Address INTEGER (4) REFERENCES Register (Address) ON DELETE CASCADE ON UPDATE CASCADE, Value INTEGER (5) );

##Table Creation begins here!.

USE SQL_STRATEGY;

#-- strategy table start here-- CREATE TABLE Strategy ( ID INTEGER PRIMARY KEY, Description TEXT NOT NULL );

DESCRIBE Strategy;

INSERT INTO Strategy VALUES (1001, 'Maximise Import from GRID'), (1002, 'Prioritise Charging the Battery'), (1003, 'Max charge Battery - Zero Exort'), (1004, 'PV to Load, Battery and Sell'), (1005, 'PV to load and Battery-No sell'), (1006, 'Max Export to Grid'), (1007, 'Safe Mode'), (1008, 'Maintenance'), (1009, 'Maximise import-No Exort');

SELECT * FROM Strategy;

#-- REGISTER TABLE START HERE-- CREATE TABLE Register ( ID INTEGER PRIMARY KEY, Name TEXT NOT NULL, Type TEXT NOT NULL, Address INTEGER NOT NULL, VarType TEXT NOT NULL, Unit TEXT );

DESCRIBE Register;

INSERT INTO Register (ID, Name, Type, Address, VarType, Unit) VALUES (1, 'Generator Charge', 'Logic', 129, 'Boolean', 'Binary'), (2, 'Grid Charge', 'Logic', 130, 'Boolean', 'Binary'), (3, 'TOU Selling', 'Logic', 146, 'Boolean', 'Binary'), (4, 'Work Mode', 'Value', 0, 'Binary', NULL), (5, 'Gen Start Charging V', 'Threshold', 123, 'Numeric', 'Volt'), (6, 'Gen Start Charging %', 'Threshold', 124, 'Numeric', '%'), (7, 'Gen Charge Curr Limit', 'Threshold', 125, 'Numeric', 'Amp'), (8, 'Grid Charge Start V', 'Threshold', 126, 'Numeric', 'Volt'), (9, 'Grid Charge Start %', 'Threshold', 127, 'Numeric', '%'), (10, 'Grid Charge Curr Limit', 'Threshold', 128, 'Numeric', 'Amp'), (11, 'Charge Curr Limit', 'Threshold', 212, 'Numeric', 'Amp'), (12, 'Max Solar Sell power', 'Threshold', 340, 'Numeric', 'Watt');

SELECT * FROM Register;

#-- STRATEGYDETAIL TABLE START HERE-- CREATE TABLE StrategyDetail ( ID INTEGER PRIMARY KEY, StrategyID INTEGER REFERENCES Strategy(ID) ON DELETE CASCADE ON UPDATE CASCADE, Address INTEGER REFERENCES Register(Address) ON DELETE CASCADE ON UPDATE CASCADE, Value INTEGER );

DESCRIBE StrategyDetail;

INSERT INTO StrategyDetail VALUES (1, 1001, 129, 0), (2, 1001, 130, 1), (3, 1001, 146, 0), (4, 1001, 0, 0), (5, 1001, 123, 0), (6, 1001, 124, 0), (7, 1001, 125, 0), (8, 1001, 126, 53), (9, 1001, 127, 99), (10, 1001, 128, 150), (11, 1001, 212, 0), (12, 1001, 340, 0), (13, 1002, 129, 0), (14, 1002, 130, 1), (15, 1002, 146, 0), (16, 1002, 0, 0), (17, 1002, 123, 0), (18, 1002, 124, 0), (19, 1002, 125, 0), (20, 1002, 126, 0), (21, 1002, 127, 0), (22, 1002, 128, 0), (23, 1002, 212, 0), (24, 1002, 340, 0), (25, 1003, 129, 0);

SELECT * FROM StrategyDetail;

SHOW DATABASES; use SQL_Strategy; show tables;

About

smart IoT project using C# for Modbus hybrid inverter, connect with AWS cloud via MQTT, control Builing by BMS

Topics

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages