This repository helps the user to select optimum Delta Tmin and Designs Heat Exchanger Network with minimum possible area (Area Targeting) by using the classical Pinch method.

License

Notifications You must be signed in to change notification settings

Ak724904/heat-exchanger-network-design-pinch-area-targeting

Repository files navigation

Selection of Optimum ΔTmin and Area Targeting of Heat Exchanger Network Design by Classical Pinch Method

This project contains two Jupyter Notebooks for design of a Heat Exchanger Network.
The first Jupyter Notebook provides relevant data to the user to choose optimum Minimum Temperature Difference by considering the trade-off between Heat Exchanger Area and Utility Requirement.
Based on the data and costing information, the user selects a ΔTmin and a corresponding Heat Exchanger Network is designed with Minimum Possible Area in the second Jupyter Notebook by the Classical Pinch Method.

Input for finding Optimum Minimum Temperature Difference:


An Excel file containing:
  • Stream Information
  • Supply Temperature (°C)
  • Target Temperature (°C)
  • Heat Load (kW)

Overall Heat Transfer Coefficient (W/m2.K) prompted by the Jupyter Notebook

Output to choose Minimum Temperature Difference:


  • Graph of Minimum Area vs Minimum Hot Utility Required
  • Graph of Minimum Area vs ΔTmin
  • Graph of Minimum Utility vs ΔTmin

An Excel file of 100 rows containing:
  • ΔTmin (°C)
  • Pinch Temperature (°C)
  • Ideal Minimum Hot Utility Required (kW)
  • Ideal Minimum Cooling Utility Required (kW)
  • Ideal Minimum Area Required (m^2)

If the user has costing information, he/she can make a sound decision to choose optimum ΔTmin.

Input for Heat Exchanger Network Design:


An Excel file containing:
  • Stream Information
  • Supply Temperature (°C)
  • Target Temperature (°C)
  • Heat Load (kW)

ΔTmin (°C) prompted by the Jupyter Notebook

Output for Heat Exchanger Network Design:


  • Combined Composite Curve
  • Grand Composite Curve
  • Pinch in the Grid Representation
  • Temperature Interval Diagram

An Excel file containing:
  • Problem Table algorithm for Pinch Analysis
  • Table to generate Hot Composite Curve
  • Table to generate Cold Composite Curve
  • Table for Area Targeting of Heat Exchanger Network Design

Limitations


  • It is assumed that the Heat Capacity Flow Rate (FCp) of all the streams are constant from the Supply Temperature to the Target Temperature.
  • It is assumed that the Overall Heat Transfer Coefficient (U) is constant regardless of the stream matches.
  • It is assumed that the pressure drop a stream experiences while going through a heat exchanger is within its permissible limit and no extra compressor is required.
  • It is assumed that all the streams in heat exchanger undergo pure countercurrent flow.
  • The number of units required to achieve minimum overall surface area isn't specified.

References


  • The Pinch Design Method for Heat Exchanger Networks- B. Linnhoff and E.Hindmarsh Chemical Engineering Science Vol.38, No. 5, pp. 745-763, 1983

  • Cost Optimum Heat Exchanger Networks-I. Minimum Energy and Capital Using Simple Models for Capital Cost- B. Linnhoff and S. Ahmad Computers Chem. Eng. Vol. 14, No. 7, pp.729-750, 1990

About the Author:


This Github repository is made by Abhishek Kundu, currently a final year student pursuing Bachelor of Chemical Engineering course at Institute of Chemical Technology, Mumbai, India. He can be contacted on his LinkedIn profile here for feedback and criticism.