No you can not |
@maragelis and @bigjuanpa - I have implemented memory read and memory write functions. I was able to dump whole memory of the panel, then I wrote separate software (for PC) for offline programing, and this soft uploads changes to Wemos D1 Mini via ftp and starts write command to write changes to panel. BTW - maragelis, this way I found your conversion of password containing zeroes is not correct - if you write to panel code 1001 the transformation should be 1AA1, and 0000 should be AAAA. In your code you are adding 160 (0xA0) if less than 10, which is incorrect - each 0 in password should be replaced by A :)) So the short answer is - with this software it is not possible - not supported, but in general it is possible :) |
Hi, thanks for all your work.
I start playing today and this works really good.
My question is if I can use this to connect to babyware to set some values like zone data name.
Since now my zone have the default name.
Regards.