-
Notifications
You must be signed in to change notification settings - Fork 0
/
computation
50 lines (50 loc) · 3.08 KB
/
computation
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
---------------Program Mode-------------------------------------
1 #Program-Mode | 1: Voltage-Loop
1 #Output System Generation: 0: No output, 1: Output
1 #rhox Output 0: No output, 1: Output
1 #surface Output 0: No output, 1: Output
1 #population Output 0: No output, 1: Output
1 # Performance File 0: No output, 1: Output
1 #Summary 0: No output, 1: Output
1 # Franck - Condon Matrix 0: No output, 1: Output
20 # Number of Population
---------------System-------------------------------------------
3000 #Number of Grid Points N
1 #N
1.000000e+01 Fourier
0 #id
--------------MasterEq-----------------------------------------
40 #medim00 Dimension 00
40 #medim11 Dimension 11
5 #meBand Bandwidth
5 #meBand Bandwidth
----------------OuputPaths--------------------------------------
--- System output filepath
/home/vault/mpet/mpet07/projects/paper/zerovolt/noenv
--- Summary output filepath
/home/vault/mpet/mpet07/projects/paper/zerovolt/noenv
--- Result output filepath
/home/vault/mpet/mpet07/projects/paper/zerovolt/noenv
---------------Time Evolution-----------------------------------
1 #Evaluation Method (1=expokit chebjev, 2=zvode, 3=expokit pade)
2 #Pade Coefficient for Calcs
---------------Schroedinger ------------------------------------
2 #Logical for Eigensystem Routine for Schroedinger
0
---------------------------ups -------------------------------
0 #Boolean for timestamps in the outputfiles
3.000000e+00 xrange for the 3d plots
0 append bool for performance testing
1.000000e-06 tolerance parameter for the 3d plots
---------------------------Baths -------------------------------
1 #(=1 for including fermion both, 0 otherwise)
1 (=1 for including harmonic bath, 0 otherwise
---------------------------Initial States -------------------------------
5 Initial state for time evolution. 1 for conventinal switching. 2 for pure state
---------------------------Initial States -------------------------------
1 Computation Modell
1 Computation Modell Paramter 2
---------------End Of File------------------------------------
Modes: 1 CVC Mode bias-independent | 2 Varying Gate Voltage with constant voltage |
3 CVC with heatmaps | 4 CVC biasDEPENDENT |20 Zvode Time Evolution | 30 Expokit Time Evolution |
50 Snaptshot Mode | 42...