PmodTC1 Read Data Type Mismatch #106

Open
digilentSoftware opened this issue Jul 13, 2018 · 0 comments
Open

PmodTC1 Read Data Type Mismatch #106

digilentSoftware opened this issue Jul 13, 2018 · 0 comments

Comments

@digilentSoftware
Copy link

The output "Temperatures" cluster use an interger format for both thermocouple and cold junction readings. It should use double, just like the input bundle did to form cluster. What happens is temperature reading looses resolution. should be 0.25C resolution but sofware makes it 1C.

See https://forum.digilentinc.com/topic/15498-software-error-pmodtc1lvlibreadvi/